Live AU Certificate Prices Twitter Linkedin-in Youtube Buy and Sell Global RECs Contact

Six Strategies to Improve Energy Efficiency at Food & Beverage Facilities

Share this article
As high-energy users, food and beverage facilities can strengthen their business performance through energy efficiency measures that conserve energy, reduce costs, and boost productivity. 

Food & beverage manufacturers play a vital role in the economy’s supply chain. These facilities involve energy-intensive processes to transfer ingredients as well as blend, heat, cool, store,  pack and deliver their products. With most organisations attributing over 15% of their operational costs to energy consumption, there is an immense opportunity for improved energy efficiency to lower their organisational operating costs and contribute toward corporate emission reduction targets.

Read on to discover the six energy efficiency strategies that food and beverage organisations should consider for their facilities. 

Strategy 1 — Review Compressed Air Distribution System and Compressed Air Use

Optimising a manufacturing plant’s compressed air distribution system is an effective way for the plant to reduce its carbon footprint and save a considerable amount on operational expenses. For food and beverage plants, it is common for 10-40% of total energy costs to go toward the generation and distribution of compressed air.  Considering that energy costs make up 80% of an air compressor’s total cost of ownership, it is clear how efficient equipment and system maintenance can lead to significant savings.

To optimise the compressed air system, it is important to eliminate the amount of compressed air lost through leakage. It is not uncommon for a facility to lose up to half of the energy expended to generate compressed air on leakages. Identifying leaks and repairing these enables facilities to improve their energy efficiency and reduce consumption. Although identification of major air leaks can be detected by listening for the leaks in non-production periods, a more robust and detailed analysis typically requires specialised equipment and an experienced technician.

Another issue is that a plant may use compressed air inappropriately. For instance, some operators may use compressed air to clean equipment, which is wasteful and can potentially give rise to Occupational Health and Safety (OHS) issues. Instead,  vacuuming or sweeping away debris is a safer and more energy-efficient means of cleaning.

Strategy 2 — Review Steam System

Due to the integrated role steam has throughout a facility, it is critical to have a comprehensive understanding of the plant’s heat flow and temperature requirements to make effective improvements to the plant’s thermal energy processes.

Like compressed air distribution systems, steam piping and valves are subject to leakage and subsequent wasted energy. Repairing leaks is a sensible start to reducing a facility’s steam requirement. Insulating steam piping and valving to prevent heat loss will also reduce demand on the boiler, which lowers fuel consumption and creates a safer work environment.

Beyond insulation and leak repair, there are several other energy-efficiency best practices that can be used to optimise steam generation systems:

Industrial heat exchange, or heat recovery, provides a source of clean, reliable thermal energy. Capturing and utilising the energy potential of a return heating stream is an effective way to reduce boiler demand, save on fuel costs, and reduce emissions. Because it is more energy-efficient to create hot water than it is to generate steam, it is also worth assessing heating requirements to determine if hot water can replace steam.

Strategy 3 — Consider Implementing Heat Pumps

A heat pump can potentially provide for many of a facility’s hot and chilled water needs. For hot water needs up to 90°C, an industrial heat pump is extremely efficient, requiring only a third of the energy needed to power a traditional hot water heater. For more domestic needs, such as hot water for staff amenities, a commercial heat pump set at 60 – 65oC can be used.

Commercial heat pumps can also chill water, some creating temperatures as low as -9°C. Using CO2 as a natural refrigerant instead of a chemical alternative, commercially available heat pumps also help improve a facility’s carbon footprint. In many cases, the operational efficiency of heat pumps make them a viable alternative to be considered when determining how to reduce carbon intensity and cut energy costs. 

To further reduce heating and cooling demand, the required temperatures for various applications should be assessed. It may be that cooler temperatures will suffice for various hot water applications, such as using 60oC water in place of 70oC water for cleaning purposes. In some cases, warmer temperatures – or even ambient temperature water – may suitably serve a plant’s cooling water requirements. Changing the temperature of a heating or cooling medium may result in larger heat transfer areas being required, longer heating and cooling times, and proof of cleanliness being compromised. Therefore, several factors need to be considered before making these temperature adjustments to ensure the continuation of quality operations.

If deemed viable, adjusting the water temperature profile across the processes and maximising heat regeneration across the plant will help reduce heating and cooling energy requirements, aiding energy conservation, emissions reductions, and cost savings.

Strategy 4 — Reduce Cooling Requirements

To reduce the cooling requirements for refrigerated rooms, it is imperative to minimise cold air escape. Firstly, it is important to limit the time that the refrigerated room is directly exposed to ambient air, which occurs whenever the door to a refrigerated room opens to an ambient space. When this happens, cool air migrates to the warmer environment, leaving a void to be filled by fresh air that needs to be chilled through the refrigeration system. One way to limit this exposure to the outside environment is to install roll fast doors that are activated using push buttons or vehicle sensors in the floor. Another strategy is to incorporate an airlock between the refrigerated room and the warmer external space.

Additionally, it is important to ensure proper insulation around doors and other penetrations to prevent cold air from escaping through holes and cracks. An infrared gun can be used to identify cold spots resulting from a leak.

Lastly, a facility should assess if it keeps its refrigerated space at an appropriate temperature. If the temperature can be slightly raised — from 1°C to 3°C, for instance — then the facility will require less energy to maintain suitable conditions.

Strategy 5 — Enable Pump Systems to Match Demand

Prioritising energy efficiency is important when considering a pump, fan, or other pieces of motor-driven equipment. Pumps are used for transporting ingredients, products, utilities, and effluent, making them one of the most frequently installed pieces of equipment in food and beverage plants. It is common for pumps to account for 25-50% of a facility’s total electrical usage. Reviewing and optimising the operating conditions of pumps and similar equipment can therefore have a significant impact on a plant’s energy efficiency and operational expenses.

Significant opportunities exist to reduce pumping system energy consumption through smart design, retrofitting, and operating practices. In particular, pumping applications with variable-duty requirements offer great energy and cost savings potential. Pump systems are often oversized, many by more than 20%. If a pump demand varies, retrofitting oversized systems with VSDs can better match pump output to system requirements. This retrofit can save considerable amounts of energy, as well as enhance performance, improve reliability, and reduce life cycle costs. If a process’ flow requirement is constant, then a properly-sized replacement pump may be a consideration, or alternatively, the existing pump could be throttled through flow rate control to conserve energy.

Similar to pumps, fan motors can benefit from the installation of VSDs. Whether the fans are on boilers, refrigeration units, or other equipment, a VSDVariable Speed Drive enables the fan motor to conserve energy while more accurately meeting demand. 

Strategy 6 — Maximise Capacity

Processes are generally most efficient when equipment is operating at maximum capacity. For instance, it is more efficient for a two-boiler system to have one boiler running at maximum capacity rating (MCR) with the other on standby than to have both boilers operating simultaneously at 50% MCR. Similarly, organisations that produce the same product at different sites, such as sprayed dried whole milk powder, should consider conducting long runs at one site while the other location temporarily shuts down. This has the potential to be more efficient than doing short runs across both sites as frequent equipment startups and shutdowns lead to an increased amount of non-productive energy and resource consumption, resulting in less energy-efficient operations. 

For industrial food and beverage facilities, there is often a significant opportunity to improve energy efficiency with existing infrastructure. By exploring ways to improve thermal energy retention and optimise systems to meet energy demand, facilities can identify strategies that result in considerable cost savings and improved energy efficiency.

Northmore Gordon helps industrial food and beverage facilities realise these savings. Our team of energy experts can help to identify and implement energy-saving strategies as well as to measure their impact. We are committed to finding energy solutions that meet industrial facilities’ corporate needs. Contact our team to enhance your facility’s energy efficiency strategy.   

You may also like:

Welcome to our August & September 2026 Compliance Update.
Australian Certificate Markets – August 2026 Update 
Where’s the value in renewable heat?

Latest Updates

ASRS Group 3: are you in scope and don’t know it?
September 18, 2026

Correct as at 13 September 2026.  If your company is a large proprietary company, you

Read More »
Beyond annual matching: The evolution of time-stamped RECs
August 18, 2026

For more than a decade, Renewable Energy Certificates (RECsI-RECs, GOs, TIGRsTradeable Instrument for Global Renewables (TIGR) Registry is an online platform for tracking and transferring renewable energy certificates (RECS), enabling developers to generate,verify and sell RECs. The registry is run by APX, a US company that provides infrastructure for environmental markets around the world., LGCs, ZNECs, J-Credits) have

Read More »
Solar irrigation upgrades: Don’t let certificate funding go unclaimed 
August 10, 2026

Irrigation pumps are one of the biggest hidden costs on an Australian farm. In particular, if

Read More »
SRES expansion: STC eligibility to increase from 100 kW to 1 MW from October 2026
August 6, 2026

The Australian Government has announced a major expansion of the Small-scale Renewable Energy Scheme, increasing

Read More »

Get in touch

Australia

1300 854 561 (Advisory)

1300 878 500 (Certificates)

Melbourne

Suite 1, Level 4

607 Bourke Street

Melbourne

VIC 3000

Singapore

+65 6690 2480



Singapore

1 Keong Saik Road,

Singapore 089109

Stay up to date

mailto:%20info@northmoregordon.com https://twitter.com/northmoregordon https://www.linkedin.com/company/northmore-gordon-pty-ltd https://www.youtube.com/channel/UCdGc6mABpL2XxVUCrVjYQ1g

Alternatively, complete the form and we will be in

touch with you.

https://northmoregordon.com
Services
Sectors
Upgrades
Certificates
Government Schemes
Helpful Links

What are the six energy efficiency strategies for food and beverage facilities described in the Northmore Gordon article?

The six strategies are: (1) Review compressed air distribution system and compressed air use, (2) Review steam system, (3) Consider implementing heat pumps, (4) Reduce cooling requirements, (5) Enable pump systems to match demand, and (6) Maximise capacity.

What percentage of operational costs do most food and beverage organisations attribute to energy consumption?

Most organisations attribute over 15% of their operational costs to energy consumption.

How much of a food and beverage plant's total energy costs can go toward compressed air generation and distribution?

For food and beverage plants, it is common for 10-40% of total energy costs to go toward the generation and distribution of compressed air, and energy costs make up 80% of an air compressor's total cost of ownership.

What is a safer alternative to using compressed air for cleaning equipment?

Vacuuming or sweeping away debris is a safer and more energy-efficient means of cleaning than using compressed air, which is wasteful and can raise Occupational Health and Safety (OHS) issues.

What best practices can optimise a steam generation system beyond insulation and leak repair?

Best practices include installing an economiser on the boiler to utilise waste heat, installing an oxygen trim to maximise combustion efficiency and assist stack emissions compliance, installing variable speed drives (VSDs) on induced draft and force draft fans, optimising boiler sequencing via a boiler management system in multi-boiler installations, and maximising condensate return.

How efficient are industrial heat pumps compared to traditional hot water heaters?

For hot water needs up to 90°C, an industrial heat pump is extremely efficient, requiring only a third of the energy needed to power a traditional hot water heater.

What temperature range can commercial heat pumps used for chilled water reach?

Commercial heat pumps can chill water, with some creating temperatures as low as -9°C, and some use CO2 as a natural refrigerant to help improve a facility's carbon footprint.

What strategies can reduce cooling requirements for refrigerated rooms?

Strategies include limiting exposure of refrigerated rooms to ambient air (e.g., using roll fast doors activated by push buttons or vehicle sensors, or an airlock between the refrigerated room and warmer space), ensuring proper insulation around doors and penetrations (using an infrared gun to detect leaks), and slightly raising the refrigerated space temperature, such as from 1°C to 3°C, to reduce energy needed to maintain conditions.

What share of a food and beverage facility's total electrical usage do pumps commonly account for?

It is common for pumps to account for 25-50% of a facility's total electrical usage.

How can retrofitting oversized pump systems improve energy efficiency?

Pump systems are often oversized, many by more than 20%; if pump demand varies, retrofitting oversized systems with VSDs (Variable Speed Drives) can better match pump output to system requirements, saving energy, enhancing performance, improving reliability, and reducing life cycle costs.

What does the 'Maximise Capacity' strategy recommend for multi-boiler or multi-site operations?

It is more efficient for a two-boiler system to have one boiler running at maximum capacity rating (MCR) with the other on standby than to have both operating simultaneously at 50% MCR. Similarly, organisations producing the same product at different sites should consider conducting long runs at one site while the other temporarily shuts down, rather than doing short runs across both sites, since frequent startups and shutdowns cause increased non-productive energy and resource consumption.

Who is the author of the article and what is their background?

The article is attributed to Northmore Gordon, with Craig Morgan described as a mechanical engineer with 30 years' experience, including more than fifteen years assisting organisations manage energy, greenhouse gas emissions, and the impacts of climate change, seven years focused on energy management and greenhouse gas inventory development and mitigation, and six years on renewable energy generation systems.

How does Northmore Gordon help industrial food and beverage facilities?

Northmore Gordon helps industrial food and beverage facilities realise energy savings; its team of energy experts helps identify and implement energy-saving strategies as well as measure their impact, and is committed to finding energy solutions that meet industrial facilities' corporate needs.

Images on This Page